xCAT Stage1 HOWTO (WIP)
xCAT 1.2.0.
Generic
IBM xSeries x86
IBM Intellistation x86
IBM xSeries x380 (Intel Lion)
IBM ia64 Intellistation Z Pro (Intel Big Sur)
Intel Tiger 4
IBM xSeries x382 (Intel Tiger 2)
IBM eServer e325 (Opteron)
IBM xSeries x336/x346/x236
Support
Follow the latest xCAT Redbook.
IANS:
Follow the latest xCAT Redbook.
IANS:
* Load Optimized Defaults
* Devices and I/O Ports:
- Onboard LAN = Disabled (If another PXE adapter added)
- Onboard LAN PXE Function = Disabled (If another PXE adapter added)
* Start Options:
- Startup Sequence = Floppy, CD ROM, LAN, Hard Disk
- Boot Up NumLock Status = Off
- Halt On Error = Disabled
* Advanced Setup:
- Chipset Feature:
- AGP Aperture Size (MB) = 128
* Connect Keyboard and Monitor (no Mouse)
* Cold Boot from EFI or Power on
* EFI Menu
- Select Boot option maintenance menu
- Edit Load File [Acpi(PNP0A03,0)/Pci(5|0)/Mac(some mac address)]
- Assign "Ethernet" as the Description
- From Main Menu select Change Boot Order
- Arrow to Ethernet, and press U, repeat until Ethernet is at top,
then Save and Exit
- Exit Main Menu to verify that Ethernet is listed first
- Reenter Boot option maintenance menu
- Select Cold Reset
* Systems Management (optional)
- Follow the instructions to create the systems management super
disk, follow the notes to run it, and enable the EMP port as
"always" with a rate of 19200.
- Use the xCAT EMP support for power management.
* Disconnect Keyboard and Monitor
* Rack and stack
IBM ia64 Intellistation Z Pro (Intel Big Sur)
* Connect Keyboard and Monitor (no Mouse)
* Cold Boot from EFI or Power on
* At the Intellistation splash screen Enter Setup
(no mouse necessary, just tab over)
- [Right Arrow] to Save/Exit tab
- [Tab] to Load Factory Settings, [Enter], [Tab] to Continue, [Enter]
- [Left Arrow] to General tab
- [Tab] to AC Power Failure Recovery Enabled, [Space] to check
- [Tab] to Serial Port 1 (COM):, [Down Arrow] to COM1
- [Left Arrow] to Power Events tab, check all fields ([Space],[Down Arrow])
- [Right Arrow] to Save/Exit tab, [Tab] to Save New Settings, [Enter],
[Tab] to Continue, [Enter]
- [Tab] to Exit, [Enter]
* EFI Menu
- Select Boot option maintenance menu
- Add a Boot Option
- Select Load File [Acpi(PNP0A03,0)/Pci(5|0)/Mac(some mac address)]
- Assign "Ethernet" as the Description
- Enter BootOption Data Type: N-No BootOption, Save to NVRAM: Y
- Exit from Add a Boot Option Menu
- From Main Menu select Change Boot Order
- Arrow to Ethernet, and press U, repeat until Ethernet is at top,
then Save and Exit
- Exit Main Menu to verify that Ethernet is listed first
- Reenter Boot option maintenance menu
- Select Cold Reset
* Disconnect Keyboard and Monitor
* Rack and stack
* Connect Keyboard, Monitor AND Mouse
* Upgrade BIOS to latest version, cold reset and enter setup with F2
- F9 to select Setup Defaults - F10 to Save and Exit
* Setup Systems Management
- Create SMU diskette
- Start an EFI shell
- type: map -r
- type: fs0:
- type: smu
- click: User
- click: No User Name
- click: Edit
- click: Enable User
- Enter Username: foo
- Enter New Password: bar
- Verify New Password: bar
NOTE all systems must have same username and password,
enter them in xcat/etc/passwd.tab
- Serial User Privilege Level: No Access
- LAN User Privilege Level: Administrator
- click: OK
- click: Save
- click: OK
- click: LAN
- Access Mode: Always Available
- click: Enable DHCP
- unclick: Automatically resolve Backup Gateway MAC Address
- click: Next >
- click: Enable LAN Alerting
- SNMP Community String: public
- click: New
- Destination IP Address: (Your Management Server IP)
- click: OK
- click: Next >
- click: Save
- click: OK
- click: Serial/Modem
- click: Next >
- click: Next >
- click: Next >
- click: Save
- click: OK
- click: PEF
- click: Enable PEF
- click: Enable SEL Event Messages for PEF Actions
- click: Next >
- For each Filter Setting:
- click: Filter
- Edit
- click: Enable Event Filter
- click: Enable Alerts
- click: OK
- click: Next >
- click: The first Policy Setting
- click: Edit
- click: Enable Policy Entry
- select: Policy Number: 1
- click: LAN Channel
- select: (Your Management Server IP)
- click: Configure Alert Settings
- click: New
- Alert String: "TigerAlert"
- click: Save
- click: Next >
- click: Save
- click: OK
- click: Exit
- type: exit
- remove SMU diskette
* EFI Menu
- Select Boot option maintenance menu
- Add a Boot Option
- Select Load File [Acpi(PNP0A03,0)/Pci(1E|0)/Pci(0|0)/Mac(xxxxxxxxxxxx)]
- Edit Existing Boot Option: E
- Enter New Description: Ethernet
- Enter BootOption Data Type: <Enter>, <Enter>
- Save changes to NVRAM: Y
- Exit
- Change Boot Order
- Down arrow to "Ethernet", press "U" until Ethernet is at top
- Exit
- Save NVRAM? Y
- Cold Reset
* Setup BIOS serial redirection and boot on failure (e.g. missing keyboard) Cold reset and enter setup with F2
- Advanced
- Peripheral Configuration
- Serial Port B = Enabled
- Base I/O Address = 2F8
- IRQ = 3
ESC back
- POST Error Pause = Disabled
Right Arrow to System Management
- System Management
- Console Redirection
- Serial Console Redirection = Enabled
- Baud Rate = (must = serialbps in site.tab)
- Terminal Type = VT100+
- Remove Console Reset = Enabled
ESC back
- F10 to Save and Exit
* Disconnect Keyboard, Monitor, and Mouse
* Rack and stack
IBM xSeries x382 (Intel Tiger 2)
* Connect Keyboard, Monitor AND Mouse
* Upgrade BIOS to latest version, cold reset and enter setup with F1, (F2 for Tiger 2)
- F9 to select Setup Defaults - F10 to Save and Exit
* Setup Systems Management
- Create or obtain a Diag/Util CD
- Start an EFI shell
- type: map -r
- type: fs0:
- type: cd Utilities
- type: cd SMU
- type: smu
- click: User
- click: No User Name
- click: Edit
- click: Enable User
- Enter Username: foo
- uncheck: Clear Password
- Enter New Password: bar
- Verify New Password: bar
NOTE all systems must have same username and password,
enter them in xcat/etc/passwd.tab
- Serial User Privilege Level: No Access
- LAN User Privilege Level: Administrator
- click: OK
- click: Save
- click: OK
- click: LAN
- Access Mode: Always Available
- click: Enable DHCP
- unclick: Automatically resolve Backup Gateway MAC Address
- click: Next >
- click: Enable LAN Alerting
- SNMP Community String: public
- click: New
- Destination IP Address: (Your Management Server IP)
- click: OK
- click: Next >
- click: Save
- click: OK
- click: PEF
- click: Enable PEF
- click: Enable SEL Event Messages for PEF Actions
- click: Next >
- For each Filter Setting:
- click: Filter
- Edit
- click: Enable Event Filter
- click: Enable Alerts
- click: OK
- click: Next >
- click: The first Policy Setting
- click: Edit
- click: Enable Policy Entry
- select: Policy Number: 1
- click: LAN Channel
- select: (Your Management Server IP)
- click: OK
- click: Save
- click: OK
- click: Exit
- type: exit
- remove CD
* EFI Menu
- Select Boot option maintenance menu
- Add a Boot Option
- Select Load File [Acpi(PNP0A03,0)/Pci(1F|0)/Pci(0|0)/Mac(xxxxxxxxxxxx)]
- Make new entry: N
- Enter New Description: Ethernet
- Enter BootOption Data Type: <Enter>, <Enter>
- Save changes to NVRAM: Y
- Exit
- Change Boot Order
- Down arrow to "Ethernet", press "U" until Ethernet is at top
- Down arror to "EFI Shell [Built-in]", press "U" until under CD/DVD options.
(Boot order should be: Ethernet, CD/DVD options, EFI Shell, etc...)
- Exit
- Save NVRAM? Y
- Cold Reset
* Setup BIOS serial redirection and boot on failure (e.g. missing keyboard) Cold reset and enter setup with F1 (F2 for Tiger 2)
- Devices and I/O Ports (Tiger 2: Advanced/Peripheral Configuration)
- Serial Port B = Enabled
- Base I/O Address = 2F8
- IRQ = 3
ESC back
- Advanced
- POST Error Pause = Disabled
- Startup Options (Tiger 2: System Management)
- Keyboard NumLock State = 0ff (x382 only)
- Post On Self Test = Normal (x832 only)
- Console Redirection
- Serial Console Redirection = Enabled
- Baud Rate = (must = serialbps in site.tab)
- Flow Control = XON/XOFF
- Terminal Type = VT100+
- Remove Console Reset = Enabled
ESC back
- F10 to Save and Exit
* Disconnect Keyboard, Monitor, and Mouse
* Rack and stack
* Flash Management Processor (BMC) to 1.42 or later.
* Flash BIOS to latest version (1.31 or later).
Remove the power cord. Count to 10,
restore power cord.
* Reboot and press [F1] to enter BIOS.
* Load Default Settings
* Devices and I/O Ports
- Serial Port Setup...
- Serial port A: Enabled
- Base I/O address: 3F8
- Interrupe: IRQ 4
- Serial port B: Disabled
* Startup Options
- Startup Sequence
- First Startup Device: Network
- Second Startup Device: CD/DVD-ROM
- Third Startup Device: Removable
- Forth Startup Device: Hard Disk
- QuickBoot Mode: Disabled
- Boot Diagnostic Screen: Enabled
- Boot Fail Count: Disabled
- NumLock: Off
* Advanced Setup
- Chipset Configuration
- SRAT ACPI Table: Enabled (for NUMA aware OS)
- Node Memory Interleave: Disabled (for NUMA aware OS)
- Node Memory Interleave: Enabled (for non-NUMA aware OS)
- Console Redirection
- Console Redirection: On-board COM A
- Baud Rate: 57.6k
- Console Type: vt100 plus
- Flow Control: XON/XOFF
- Console connection: Direct
- Continue C.R. after POST: On
SOL Notes:
* Advanced Setup
- Console Redirection
- Console Redirection: On-board COM A
- Baud Rate: 9600
- Console Type: vt100
- Flow Control: CTS/RTS
- Console connection: Direct
- Continue C.R. after POST: On
- Baseboard Management Controller
- Change COM port Setting: Yes
- COM post on BMC: CLI
* Save Settings
* Collect MACs (stage2), then stage3 the node.
* Flash Management Processor (BMC) to 1.03 or later.
* Flash BIOS to latest version (1.04 or later).
Remove the power cord. Count to 10,
restore power cord.
* Reboot and press [F1] to enter BIOS.
* Load Default Settings
* Devices and I/O Ports
- Serial port A: Port 3F8, IRQ 4
- Serial port B: Disabled
- Remote Console Redirection
- Remote Console Active: Enabled
- Remote Console COM Port: COM 1
- Remote Console Baud Rate: 9600 (anything is supported, 9600
was tested)
- Remote Console Text Emulation: VT100/VT220
- Remote Console Keyboard Emulation: VT100/VT220
- Remote Console After Boot: Enabled
- Remote Console Flow Control: Hardware
* Startup Options
- Startup Sequence
- First Startup Device: CD ROM
- Second Startup Device: Diskette Drive 0
- Third Startup Device: Network
- Forth Startup Device: Hard Disk
- Wale On LAN: Disabled
- Planer Ethernet PXE/DHCP: Planer Ethernet 1
- Boot Fail Count: Disabled
* Advanced Setup
- CPU Options
-
Hyper-Threading Technology: Disabled
SOL Notes:
You must have smbridge RPM installed. Use the xCAT sol.x336 method in
conserver.cf. Look at $XCATROOT/samples/etc/conserver.cf for an example.
Addtional Settings (do the above first)
* Devices and I/O Ports
- Remote Console Redirection
- Remote Console Baud Rate: 19200
* Advanced Setup
- Baseboard Management Controller (BMC) Settings
- System BMC Serial Port Sharing: Enabled
- BMC Serial Port Access Mode: Dedicated
* Save Settings
* If you switched to using SOL, you must remove the power cord for 5 sec.
* Collect MACs (stage2), then stage3 the node.